28
7. CONDENSED WATER DISPOSAL OF OUTDOOR UNIT (HEAT PUMP UNIT ONLY)
There are 2 holes on the base of Outdoor Unit for condensed water to flow out. Insert the drain elbow
to one of the holes.
To install the drain elbow, first insert one portion of the hook to the base (portion A), then pull the drain
elbow in the direction shown by the arrow while inserting the other portion to the base. After the
installation, check to ensure that the drain elbow clings to base firmly.
If the unit is installed in a snowy and chilly area, condensed water may freeze in the base. In such a
case, please remove plug at the bottom of unit to smooth the drainage.