MCQUAY Service Guide Book Controller Configuration
32
5.6 Hardware Setting – SLM8
There are 2 jumpers on SLM8 option to control
the board function as shown in Picture below.
Summary of Hardware Setting as table below:
Jumper Short Open
20-30C
(Set Temp
Range)
20°C – 30°C 16°C – 30°C
(Default)
TURBO_
QUIET*
Disable turbo &
quiet fan speed
(Default)
Enable turbo &
quiet fan speed
* Only applicable to model with built in Turbo or
Quiet features.