McQuay M5HDC Spécifications

Naviguer en ligne ou télécharger Spécifications pour Climatiseurs à système divisé McQuay M5HDC. McQuay M5HDC Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - M5HDC025AR

CatalogHorizontal Ducted Condensing UnitM5HDC-2010Models: M5HDC020AR M5HDC025AR

Page 2 - Table of Contents

9M5HDC-2010Application InformationControllerSLMOperation GuideCOOLDRYHEATMEDHIGHAUTOMODETEMPSENSORON/OFFSLEEPLOWTIMER82593641FANFAN ON/OFFTEMPSLEEPTIM

Page 3 - Nomenclature

10M5HDC-2010Application InformationInstallation GuidelineSafety Precautions WARNING CAUTIONInstallation and maintenance should be performed by qualifi

Page 4 - M 5 HDC 020 A R

11M5HDC-2010Application InformationInstallation of Indoor UnitFor installation of indoor unit, please refer to the indoor unit technical manual.Instal

Page 5 - Product Line-Up

12M5HDC-2010WiringWiring Electrical Connections• Wiring regulations on wire diameters differ from country to country. Please refer to your LOCAL ELEC

Page 6 - M5HDC-AR

13M5HDC-2010Application InformationPiping Connection To The Units• Align the center of the piping and sufciently tighten the are nut with ngers.•

Page 7 - Features

14M5HDC-2010Diagram 24) After evacuation, unscrew the spindle (diagram 2) for the gas to run to indoor unit.• The refrigerant gas has already charge

Page 8

15M5HDC-2010Application InformationOverall Checking• Ensure the following, in particular :- 1) The unit is mounted solidly and rigid in position. 2

Page 9 - Refrigerant Circuit Diagram

16M5HDC-2010Application Information Special Precautions When Dealing with Refrigerant R410A Unit(1) What is new refrigerant R410A? R410A is a new HF

Page 10 - Operation Guide

17M5HDC-2010 Application Information(5) Handling and installation guidelines Like R22 system, the handling and installation of R410A system

Page 11 - CAUTION

18M5HDC-2010Sound DataSound DataSound Pressure LevelExt. Static (mmAq)125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz6.5High 42 39 36 34 28 22 17 38 336.0Mediu

Page 12 - Installation of Outdoor Unit

M5HDC-2010 Table of Contents“McQuay” is a registered trademark of McQuay International. All rights reserved.© 2010 McQuay International. All rights re

Page 13 - Refrigerant Piping

19M5HDC-2010Sound DataM5CC020CRNC CurveM5CC025CRNC CurveSound pressure level (dB, ref 20µPa)010203040506070125 250 500 1000 2000 4000 8000Octave-band

Page 14 - Vacuuming and Charging

20M5HDC-2010Engineering and Physical DataEngineering And Physical DataGeneral Data - Heat Pump (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY

Page 15 - M5HDC025AR 80 200 400

21M5HDC-2010Engineering and Physical DataComponents Data (R22)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

Page 16 - Standard Operating Condition

22M5HDC-2010Engineering and Physical DataSafety DevicesOPENkPa / psiCLOSEkPa / psiOPEN kPa / psiCLOSEkPa / psiDISCHARGE THERMOSTAT SETTING °C / °F1) A

Page 17 - Application Information

23M5HDC-2010Performance DataPerformance Data1st Step Extrapolation of Indoor WBFind TC, SC for (a) Indoor: 24°C DB, 15°C WBOutdoor: 35°C DB(b) Indoor:

Page 18

24M5HDC-2010Performance DataDetails:1st Step:Indoor DB˚CIndoor WB˚COutdoor DB, ˚C 35TC (kW) SC (kW)...2415...x1y116 3.36317

Page 19 - Sound Pressure Level

25M5HDC-2010Performance Data2nd Step:Indoor DB˚CIndoor WB˚COutdoor DB,˚C 35TC (kW) SC (kW)...20 15...3.29523 15x3y324 15 3.2

Page 20 - M5CC025CR

26M5HDC-2010Performance Data3rd Step:To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 23°C DB, 15°C WB Outdoor Condition:

Page 21 - Engineering And Physical Data

27M5HDC-2010Performance DataPerformance TableHeatpump (R410A)Model: M5CC020CR - M5HDC020CRCooling ModeTC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW)

Page 22 - Components Data (R22)

28M5HDC-2010Performance DataModel: M5CC025CR - M5HDC025ARCooling ModeModel: M5CC025CR - M5HDC025ARHeating ModeTC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW

Page 23 - Safety Devices

2M5HDC-2010NomenclatureIndoorNomenclatureM 5 CC 020 C RBrandM : McQuayModel NameCapacity IndexModel TypeRefrigerant“ ” : Omitted if R224 : R4

Page 24 - Performance Data

29M5HDC-2010Outline and DimensionOutline and DimensionIndoor UnitModel: M5CC020/ 025CRA B C D E F G HM5CC020CR 1041 225 1002 962 261 411 351 1065M5CC0

Page 25 - Calculation Steps

30M5HDC-2010Outline and DimensionOutdoor UnitModel: M5HDC020/ 025ARNote: Dimension in mm

Page 26

31M5HDC-2010Electrical DataElectrical DataElectrical Data - Heatpump (R410A)1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT

Page 27

32M5HDC-2010Wiring DiagramWiring DiagramHeat PumpIndoor Unit Outdoor UnitModel: M5CC020CR Model: M5HDC020AR M5CC025CR

Page 28 - Heatpump (R410A)

33M5HDC-2010Service and MaintenanceComponents Maintenance Procedure Recommended ScheduleIndoor Air FilterIndoor UnitCondensate DrainPan and Pipe1. Che

Page 29 - Heating Mode

34M5HDC-2010Service and MaintenancePre Start Up Maintenance(After Extended Shut Down)- Inspect thoroughly and clean indoor and outdoor units.- Clean o

Page 30 - Outline and Dimension

35M5HDC-2010TroubleshootingTroubleshootingError CodeHeatpump Model (Universal Board)Operation / Faulty IndicationRoom sensor contact loose / shortIndo

Page 31 - Model: M5HDC020/ 025AR

36M5HDC-2010TroubleshootingDiagnostic GuidelinesNo Cooling / HeatingUnit fail to startCheck power supply- voltage- phase- frequencyCheck settings of r

Page 32 - Electrical Data

37M5HDC-2010TroubleshootingBy means of diagnostic ow chart: No CoolingThe following chart are efficient checking procedures for troubleshooting when

Page 33 - Wiring Diagram

38M5HDC-2010TroubleshootingInsufficient CoolingHigh Discharge Pressure or LowSuction PressureDual PressureSwitchCompressorCyclingOvercurrentRelay ForC

Page 34 - Service and Maintenance

3M5HDC-2010OutdoorNomenclatureM 5 HDC 020 A RBrandM : McQuayModel NameCapacity IndexModel TypeRefrigerant“ ” : Omitted if R224 : R407C5 : R4

Page 35 - Pre Start Up Maintenance

39M5HDC-2010TroubleshootingNoisy OperationUnremoved Shipping Bolt(s)EvaporatorFanCompressorOvercharged RefrigerantLow Suction PressureWorn Compressor

Page 36 - Troubleshooting

40M5HDC-2010Exploded View and Part ListExploded View and Part ListIndoor UnitModel: M5CC020/ 025CRNote: All exploded view and part list are subjected

Page 37 - Diagnostic Guidelines

41M5HDC-2010Exploded View and Part ListNote: All exploded view and part list are subjected to change by the manufacturer without prior noticeOutdoor U

Page 38 - No Cooling

42M5HDC-2010Exploded View and Part ListNote: All exploded view and part list are subjected to change by the manufacturer without prior noticeOutdoor U

Page 39

© 2010 McQuay International www.mcquay.com Products manufactured in an ISO certified facility. This document contains the most current product in

Page 40

4M5HDC-2010Product Line-UpIndoor UnitM5CC-CRNomenclatureL2SLM 3Bare Air FilterCEEPS Drain Pan020CR AFBA X X X X X X025CR AFAA X X X X X XHandsetHeatPu

Page 41 - Exploded View and Part List

5M5HDC-2010Product Line-UpOutdoor UnitM5HDC-ARCap TubeHydrophilic CoatedRotaryCE020AR AFBA X X X X025AR AFAA X X X XHeatPumpCompressorOthersClassifica

Page 42 - Model: M5HDC020AR

6M5HDC-2010Adequate External Static PressureThe external static pressure is specially designed to blend in most of the interior design and yet to ensu

Page 43 - Model: M5HDC025AR

7M5HDC-2010Application InformationOperating RangeEnsure the operating temperature is in allowable range.HeatpumpApplication InformationHeatingCoolingO

Page 44

8M5HDC-2010Application InformationRefrigerant Circuit DiagramModel: M5CC020CR – M5HDC020AR M5CC025CR – M5HDC025AR70034 095378

Commentaires sur ces manuels

Pas de commentaire